VisualView HMI/SCADA Development Software package for only $849.99

 
     
 

HMI Screen

 
 
   
   
 
PC based PLC HMI/SCADA Software for Allen Bradley, Siemens, Omron, GE, Modbus and more

Cost Effective - No tag usage fees with unlimited screens.

Free Updates - All future updates are included in the purchase price.

HMI Features:

  • Unlimited tag count
  • Unlimited external connections
  • Unlimited graphic screens 
  • Unlimited HMI to HMI tag data connections 
  • OPC Data Access Server (DA 2.xx)
  • OPC Data Access Client (Redundant -Hot Standby)
  • Extensive help files
  • Graphics editor
  • Runtime screen printing
  • Scripting engine (not required for graphic animation or user interaction)
  • Trending
  • Data logging
  • Custom reporting (ASCII, DOC, XLS,CSV, TAB, HTML, Printer)
  • Alarming with grouping and logging
  • Event logging
  • Recipes
  • User Graphic Library
  • Complex MA (Manual/Automatic) graphic object
  • Video in user windows
  • English and Spanish language support (Configuration and runtime programs. Help files excluded.)
  • Hard drive free space monitoring and alarming
  • ODBC (Open Database Connectivity)
  • Scheduler - start/end trigger based on time/day/date/holiday/etc
  • Task scheduler - one time or recurring events

Included Drivers:

  • Allen Bradley (Redundant - Hot Standby) RSLinx not required
    • DF1 for PLC5, SLC500, SLC 5/01 - 5/05, MicroLogix 
    • Ethernet for ControlLogix, CompactLogix, FlexLogix
      Ethernet PCCC for SLC, MicroLogix, SLC 5/05, PLC5
  • Bacnet/IP (Redundant - Hot Standby)
    • Analog Input, Analog Output, Analog Value, Binary Input, Binary Output,
    • Binary Value, Loop, Multi State Input, Multi State Output, Averaging,
    • Multi State Value, Life Safety Point, Life Safety Zone
    • Read Property, Write Property
  • Delta computer systems - motion controllers - Delta motion control protocol (DMCP)
    • TCP/IP and UDP/IP
    • Read and write all files and elements
    • Collect plots using Method 2 - Advanced (No limit on plot size) 
  • DNP3 Master
    • RS-232, RS-485 and TCP/IP 
  • DNP3 Outstation emulation
    • TCP/IP 
  • Enron MODBUS
    • RTU (RS-232) and TCP/IP
    • RTU over TCP/IP
    • All register types
    • Fatek (Facon)
      • RS-232/485, TCP/IP and UDP/IP
      • All register types
      • Long break or long break free
    • GE SRTP  (Redundant - Hot Standby)
      • All register types
    • IDEC (OpenNet) (Redundant - Hot Standby)
      • All register types
    • Keyence PLC (Redundant - Hot Standby)
      • All register types
    • K-Sequence (Redundant - Hot Standby)
      • Automation Direct (DirectLogic, Koyo)
      • All register types
    • Master-K LS/LG Industrial Systems  (Redundant - Hot Standby)
    • Mewtocol-COM (Panasonic/Matsushita/Aromat/NAIS) (Redundant - Hot Standby)
    • Mitsubishi FX 0,1,2,3 (Redundant - Hot Standby)
      • All register types
      • Bit, Word, Longword, Float
    • Mitsubishi Serial (Redundant - Hot Standby)
      • Protocol 3C, Format 1 or 4, Checksum or no checksum
      • All register types
      • Bit, Word, Longword, Float
    • Mitsubishi TCP/IP (Redundant - Hot Standby)
      • Protocol 3E
      • All register types
      • Bit, Word, Longword, Float
    • MODBUS/J-Bus Serial (RS-232/485) ASCII
      • Master
      • Bit, Float, String, Word
    • MODBUS/J-Bus Serial (RS-232) RTU (Redundant - Hot Standby)
      • Master and Slave
      • Bit, Float, String, Word
    • MODBUS/J-Bus Serial (RS-485) RTU
      • Master
      • Bit, Float, String, Word
    • MODBUS/J-Bus TCP/IP (Redundant - Hot Standby)
      • Master and Slave
      • Bit, Float, String, Word
    • ODBC (Open Database Connectivity)
      • All dynamic tag values output to unlimited number of concurrent databases
      • Can be the source for analog or digital process variables from unlimited number of concurrent databases
    • Omron FINS (RS-232) (Redundant - Hot Standby)
      • C, CV or CS/CJ mode
      • All register types
      • Bit, Word, Longword, Float
    • Omron FINS (TCP and UDP) (Redundant - Hot Standby)
      • C, CV or CS/CJ mode
      • All register types
      • Bit, Word, Longword, Float, String
    • Omron Hostlink/SYSMAC-WAY (Redundant - Hot Standby)
      • All register types
      • Bit, Word, Longword, Float
    • Omni flow computers (Enron MODBUS) RS-232 and TCP
      • All register types
      • All report types
    • Saia-Burgess
      • Serial-S-Bus (RS232/485)
      • Ether-S-Bus
      • Registers, Counters, Timers, Flags, Inputs, Outputs, Data blocks
      • All data types - bit, integer, float, string
    • Siemens S7-200 (PPI) (Redundant - Hot Standby)
    • Siemens S7-200 (TCP/IP CP 243-1)
      • Inputs, Outputs, Analog Inputs, Analog Outputs, Variable memory, Timers, Counters, Special memory
      • All data types - bit, byte, word, double word, float, timer, counter, string
    • Siemens S7-300/400 (MPI) (Redundant - Hot Standby)
      • Inputs, Outputs, Internal memory, Timers, Counters
      • All data types - bit, byte, word, double word, float, timer, counter
    • Siemens S7-300/400/1200 (TCP) (Redundant - Hot Standby)
      • Inputs, Outputs, Internal memory, Timers, Counters, Data blocks
      • All data types - bit, byte, word, double word, float, timer, counter
    • SNMP (Simple Network Management Protocol) Version 1
      • UDP
      • Traps with logging
      • GetRequest/SetRequest
    • Toshiba ASCII computer link protocol (RS-232/485)
      • X, Y, R, S, T, C, D, L registers
      • Bit, Word, Longword, Float, String
    • Toshiba ASCII computer link protocol (UDP/IP)
      • X, Y, R, S, T, C, D, L registers
      • Bit, Word, Longword, Float, String

Supported Operating Systems:

  • Windows XP
  • Windows 7
  • Windows 8
  • Windows 10
 

 

 

 

   

 

 Full Featured HMI/SCADA Package $849.99